Novenco AirBox versions

It's a generic configurator for products manufactured by the Novenco Group
3.4
Dec 11, 2023
Review
3.3
Aug 21, 2015
3.2
Jan 16, 2015
Review
3.0
Oct 26, 2013
2.9
Oct 11, 2011
Review
2.8
Jun 28, 2011
2.6
Nov 8, 2010

What's new

v3.4 [Mar 30, 2016]
- ABB motors are added.
- Hoyer motors are added.
- Specific Fan Power (SFP) is added in report.
- Horizontal mounting is added for Zerax Micro fans size 250/160 - 500/160.
- New AirBox logo aligned with Novenco Building & Industry design guidelines.
- For ACW it is now possible to select Casing Thickness = "Any".
- Inlet cones for AZN Micro sizes 280/160, 355/160 and 450/160 are added.
- Weights for Zerax Micro fans size 250/160 - 500/160 were wrong.
- Weights for inlet cones and mounting feet for AZN 1800/560 - 2000/560 were wrong.
- IP class information was sometimes missing in report.
- Updating a solution with Specific Fan selected failed.
- It was not possible to select inlet silencer spare part for ACW.
- EU Eco design information was sometimes in the report even if rules did not apply for the solution.
- Current for Domel motors was unprecise.

v3.2 [Jan 16, 2015]
- It is now possible to select frequency converter for Bartec motors in Atex/Ex calculations.
- China Classification Society (CCS) marine classification is added.
- Centrifugal fan calculations with fixed speed now produces more solutions. New solutions might have pressure higher than requested.
- Deviation from requested pressure and flow when calculating fans by fixed speed is now shown in the list of solutions.
- New calculation option in Options menu: Max. pressure difference in percentage. Used for fixed speed calculations.
- Dutch and German translations are updated.
- New EU EcoDesign implementation. New interpretation of rules
- Default name is now suggested when using SaveAs button in the Configuration window.
Bug fixes:
- ZerAx and Novax silencer material description was wrong in the program and in the report. Wrong description HDG is corrected to AluZink.
- Motor Current and Rated Current was wrong when selecting Vacon frequency converter.
- Dimensions for wireguard were missing for ZerAx Large size 1800 - 2000.
- No Novax solutions smaller than fan size 900 were calculated if a diffusor was selected.
- Startup times for Bartec motors were to high.
- ZerAx calculations with very low static pressure could cause error.
- Novax F400 max speed were incorrect.
- Wrong unit on Moment of Intertia in the report.

Alternative downloads

Air Attack
Air Attack
Free
rating

Experience a wonderful nostalgic trip back into the history of flight simulation

SMA Off-Grid Configurator
SMA Off-Grid Configurator
Free
rating

SMA Off-Grid Configurator plans off-grid systems that saves time and money.

Onda HTS
Onda HTS
rating

Configure Onda S.p.a. products.

1888 Quick Flow Chart Creator
1888 Quick Flow Chart Creator
rating

Free and user-friendly flow chart creator to draw customized flow chart quickly.

Air Cooled Heat Exchanger Design
Air Cooled Heat Exchanger
rating

It shows the thermal design and sizing calculations of cooled heat exchangers.